Locking compression plates are more difficult to remove than. Types of locking plates fixed angle only one way screw engages plate without crossthreading variable angle screw can be locked within a cone, clearance angle up to 15. Therefore, this study compares the complication rates of locking compression plate lcp removal and conventional non locking plate removal. Comparison of the general situation between two groups index internal fixation with minimally invasive adjustable plate group n20 internal fixation with locking compression plate group n24 p value age years 39.
The visual, optical and scanning electron microscopy results indicated the presence of beach marks, intermetallic inclusions, corrosion pits and striations indicating fatigue. The locking screws enable the anatomicallypreformed plates to be fully effective the use of lcp implants enables early and active mobilization, even in the case of complex epimetaphyseal fractures and osteoporosis with its line of lcp implants, synthes. Metaphyseal locking compression plate as an external fixator. A pitfall in fixation of distal humeral fractures with precontoured locking compression plate. Briefly, the locking plate behaves like an external fixator but. However, the concept of the locking plate itself often continues to be misunderstood and consequently even misjudged. High compression locking pegs help to reduce and stabilize dorsal fragments by means of a differential pitch effect. Pdf metaphyseal locking compression plate as an external. Metaphyseal locking compression plate as an external fixator for the distal tibia sven a. A mechanical comparison of the locking compression plate. Fluoroscopy should be used to verify accurate plate placement prior to screw fixation. A desire to preserve the blood supply to the bone by eliminating, or at least reducing, plate contact fig. Five synthetic bars synbone osteoporotic bone were initially tested in compression and the youngs modulus determined. The benefits of locking implants include elimination of the need for plate bone compression, greater construct stiffness, and biomechanical stability as compared to nonlocking implants, resistance.
To determine if locking compression plates lcp are mechanically advantageous compared to lowcontact dynamic compression plates dcp when used as a bridging plate in a synthetic model of osteoporotic bone methods. Recently we coined the term supercutaneous plating using a locking compression plate lcp as an external fixator. The locking compression plate lcp is a new screwplate system that offers the possibility of inserting conventional and locking head screws into the specially designed combination holes. This part, also called a bone plate, is used to immobilize fractured bone segments in order to promote proper healing. A pitfall in fixation of distal humeral fractures with pre. There is no tension on the bone compression is eliminated between the plate and bone the periosteum is undamaged and circulation is retained the plate does not have to be precisely shaped to the bone to provide stability. One of the fracture surfaces from the failed component was investigated for surface topographical features. Clinicians have the impression that hardware removal of lcps are more difficult and associated with more complications than conventional non locking plates. A series of biomechanical in vitro experiments were performed using composite humerus sawbone as the bone model. Locking compression plate in musculoskeletal oncology a.
The locking compression plate system has many similarities to conventional plate fixation methods, but with a few important improvements. Large fragment locking compression plate lcp technique. Clinical evaluation of locking compression plate fixation for. Ankle arthrodesis utilizing an anterior locking compression plate. Plates will compress the joint linearly along the compression arms, so plate positioning should account for this.
Pdf locking compression plate loosening and plate breakage. The locking compression plate lcp is a new development of the screwplate system that allows the combination of standard plate technology and locking screws with angular stability. Pdf open reduction and internal fixation of fractures involves the use of metallic implants to support bone reduction. Large fragment locking compression plate lcp system locking screw features plates features locking screw with torx drive recess the torx drive recess provides improved torque transmission to the screw and minimizes the possibility of cross thread. While using this approach has several advantages, including minimal soft tissue disruption, preservation of natural biology and minimal blood loss, there is an increased risk for axillary nerve damage. The purpose of our study was to assess the effectiveness of a contoured standard 4. Since patient file was not available, therefore, it was not possible to comment on the. Medical implants are manmade devices, in contrast to a transplant, which is a transplanted biomedical tiss. Large fragment locking compression plate lcp system. In addition, due to the low boneplate contact while using locking screws, the risk of disturbances to periosteal circulation is minimised. Conventional platescrew systems require precise adaptation of the plate to the underlying bone. Dynamic compression locking plate dcp narrow youtube. The locking compression plate lcp is a new screw plate system that offers the possibility of inserting conventional and locking head screws into the specially designed combination holes. All locking screws can be placed onaxis with the internal plate threads or up to 15degrees offaxis in any direction.
This study aimed to evaluate the outcome of using a locking compression plate lcp as a definitive external fixator in the management of infected nonunion of the humeral diaphysis after failure of internal fixation. The anterior approach to ankle and anklehindfoot arthrodesis with an anteriorly placed locking compression plate provides satisfactory results with 100% fusion in the current series. It also offers a pdf compression tool, but you will have to upgrade to pro version to use that feature. The locking compression plate lcp was devised by combining the features of an lcdcp and a pcfix. The principle of the locking compression plate lcp is represented by the combination of two completely different anchorage technologies and two opposed principles of osteosynthesis in one implant it combines the principles of conventional plate osteosynthesis for direct anatomical reduction with those of bridging plate osteosynthesis.
Surgical technique this technique is for hybrid plating, which is how most locked plates are utilized currently reduce the joint via compression if applicable lag screws placed before locking screws reduce shaft to plate if applicable, then lock the following technique slides are from prior version of this talk created by thomas f. Apply direct pressure over the dorsal aspect of the radius prior to locking the screw to the plate to achieve full compression. Locking compression plate depuy synthes locking compression plate f a b reduction maintained under a load lcp combihole stable bridging of comminuted fractures the stable plate screw connection reduces the risk of secondary loss of reduction in the epiphyseal and metaphyseal regions the screws are locked in the plate, and. Clinical evaluation of locking compression plate fixation for this information is current as of october 25, 2010 reprints and permissions permissions link. Case report dynamization of the locking compression plate for. Dynamic compression locked plate has a combi hole which permit the insertion of standard head screws and of threaded locked head screw. Case report dynamization of the locking compression plate.
The claw ii polyaxial compression plates locking screw holes have been designed to accept both 2. All surgical techniques are available as pdf files at. Insert a high compression locking peg to compress the plate down to the bone. Tightening of the screw compresses the plate to the.
Metaphyseal locking compression plate as an external. One end of the multifunctional hole allows using cortex screw to perform dynamic compression and the other end allows using locking screws for angular stability. The lcp has a combi hole which permits the insertion of standard. This surgical technique applies to the depuy synthes lcp locking compression plate systems and product lines listed below, which include but are not limited to the. Compression plate lcp, with combination holes has come into use. An anteriorly placed locking compression plate and screws were used for internal fixation in all cases.
Large fragment locking compression plate lcp technique guide. Basic principles and techniques of internal fixation of. The locking compression plate group that used the compression features of the plate, without the lag screw, had less joint displacement and higher stiffness than control p pdf files in plain text makes extraction, program analysis, and new software design possible. Stiffness of the locking compression plate as an external. Locking plate and screw systems have advantages over the conventional screw system. When using a locking screw onaxis, the appropriate locking drill guide is. The locking compression plate lcp system offers a number of advantages in fracture fixation combining angular stability through the use of locking screws with traditional fixation techniques.
Effectiveness of locking versus dynamic compression plates. Biomechanical testing of the locking compression plate. The locking plate has progressively but especially very recently become part of todays orthopaedic and traumatology surgeons arsenal of osteosynthesis techniques. This study explores the clinical outcome of treating distal femoral fractures with a locking compression plate using a posteriolateral novel.
Original article therapeutic effects of minimally invasive. Different types of screws conventional screws cortex screw with or without shaft cancellous bone screw with or without shaft locking head screws lhs selftapping lhs selfdrilling, selftapping lhs 5. The use of minimally invasive plate osteosynthesis mipo via anterolateral deltoid splitting has good outcomes in the management of proximal humerus fractures. The trauson mini locking plate system is designed to provide a solution for the treatment of small bone fractures, osteotomies, nonunions, malunions, fusion of small bones, and small bone fragments, particularly in osteopenic bone.
The synthes locking compression plate lcp is part of a stainless steel and titanium plate and screw system that merges locking screw technology with conventional plating techniques. Dynamization, locking compression plate, bone nonunion. Dynamization of the locking compression plate for treating tibia nonunion. An orthopedic plate is a form of internal fixation used in orthopaedic surgery to hold fractures in place to allow bone healing. If you are desperate to compress pdf files on your android, then give it a try. Feb 03, 2017 the locking compression plate lcp is a new development of the screwplate system that allows the combination of standard plate technology and locking screws with angular stability.
Thread the locking drill guide pn dc4180 into one of the proximal screw holes. Infected nonunion of the humeral diaphysis is a challenging problem for orthopedic surgeons. This app offers a range of tools to manipulate pdf files, such as split, merge, lock and convert, etc. Locking screw with selftapping flutes less surgical steps cortical thread with large core. Locking compression plate lcp implants are intended for temporary. The flate compression operation is found in the pdf reference manual and the postscript reference manual from adobe systems. The locking compression plate lcp is an anglestable fixator intended for intracorporeal application. This makes the implant particularly suitable for use in poor bone stock and complex joint fractures, especially in the epimetaphyseal area. Apr 22, 2016 locking compression plate lcp dynamic compression unit conical and threaded unit 4. To investigate in vitro the mechanical stability of a locking compression plate lcp construct in a simulated diaphyseal fracture of the humerus at increasing distances between the plate and bone. Evaluation of results of locking compression plate in. Ankle arthrodesis utilizing an anterior locking compression. Clinical effect of locking compression plate via posterolateral. In selected cases, it can be applied externally in an extracorporeal location to function as.
The use of this technique in periarticular areas is facilitated by the development of anatomical plates with various screw sizes. Additional screws outside of the plate were used at the discretion of the surgeon. A failure study of a locking compression plate implant. Plate tacks pn 40250010 can be placed either through any locking screw hole or between the compression arms. This surgical technique applies to the depuy synthes lcp locking compression plate systems and product lines listed below, which include but are not limited to the following indications. Locking plates are often more challenging than plates and screws, because with this modality, fracture fragments cannot easily be pulled towards the plate as they can be with conventional screws. Clinical evaluation of locking compression plate fixation.
An implant is a medical device manufactured to replace a missing biological structure, support a damaged biological structure, or enhance an existing biological structure. Locking compression plate loosening and plate breakage. Locking compression plate in the treatment of forearm. It may be necessary to use other techniques such as whirlybird screw devices, or to use ordinary screws in the locking plate to achieve alignment. Fracture repair has taken a major step forward with the adoption of locking compression plates as the standard treatment for broken bones. Sep 29, 2015 dynamic compression locked plate has a combi hole which permit the insertion of standard head screws and of threaded locked head screw. Evaluation of results of locking compression plate in distal femur fractures anuj kumar lal1, s k kaushik2. Principles and clinical application of the locking. Synthes, zeist, the netherlands by the senior author p. Basic principles and techniques of internal fixation of fractures. Jan 11, 20 locking compression plates lcps have been introduced in the last decade.
Locking compression plate in musculoskeletal oncology a friend in need masood umer, mbbs, kashif abbas, mbbs, shahid khan, mbbs, haroon ur rashid, mbbs section of orthopaedic surgery, department of orthopaedic surgery, the aga khan university hospital, karachi. The displacement of posterior pelvic ring was reduced by extrusion, traction table 1. Stiffness of the locking compression plate as an external fixator for treating distal tibial fractures. Locking screws can be placed in each hole of the plate because the screws are tightly locked in the plate. Locking plates and their place in fracture surgery. A locking compression plate as an external fixator for. The locking compression plate had been separated in two pieces. Locking compression plate fixation of equine tarsal. Locking compression plates lcp combi holes allow fixation with locking screws in the threaded section, for angular stability, and cortex screws in the dynamic compression unit dcu section, for compression locking screws do not rely on plate tobone compression to resist patient load, but function similarly to multiple, small, angled. A failure study of a locking compression plate implant sciencedirect. However, locking compression plate technology features unicortical locking screws that can be an internal fixator that can act as a bridge over compromised bone. Surgical technique lcp locking compression plate depuy synthes 1. The lcp was developed to give surgeons the opportunity to combine principles of internal fixation and dynamic compression, depending on the fracture site, as it contains.
In this case study a failed locking compression plate was investigated. Pdf overview of the locking compression plate and its clinical. Minimally invasive plate osteosynthesis with a locking. The pdf of the article you requested follows this cover page.